Coaxial Cables

CK175/H2C4:RG175AF + 4 x 0.22mm2 + 2 x 0.75mm2

Construction

Inner conductor1 Plain copper 9x0.10mm
Dielectric Lowdensity PE Φ1.50±0.08mm
Outer conductor(shield) Tinned copper 72x0.10mm
Shiel dcoverage 90%
Sheath PVC Φ2.80±0.13mm
Inner conductor2 Plain copper 4x0.22mm2
Insulated cores2 PVC 4xΦ1.00±0.10mm
Inner conductor3 Plain copper 2x0.75mm2
Insulated cores3 PVC 2xΦ1.70±0.10mm
Overall sheath Φ7.00±0.20mm

Electrical & Mechanical Characteristics

Impedance :75±5Ohm

Nominal capacitance :67pF/m

Velocity of propagation :66%

Insulation resistance :>2000Mohm.Km

Inner conductor resistance :250Ohm/Km

Outer conductor resistance :35Ohm/Km

Operating temperature range :-25°C-+80°C

Cores resistance 0.22mm2/0.75mm2 :82Ohm/Km/26Ohm/Km

Operatig Voltage(max) :0.25KV/0.3KV

Test Voltage :1.2KV/2.0KV

Copper weight :27.45Kg/Km

Cable weight(approx.) :82.75Kg/Km

fectiveness :>50dB

Attenuation

Frequency(MHz) Attenuation(dB/100m) Attenuation(dB/100ft)
50 19.2 5.85
100 27.9 8.51
200 40.7 12.41
400 59.2 18.05
500 67.5 20.58
600 72.6 22.13
860 91.1 27.77
1000 101 30.79

Return Loss

30-300MHz >20dB
300-600MHz >20dB
600-900MHz >20dB